Home
| Recruitment | Agents & Distributors | Contact





Slack and Parr Hydraulics





flow dividers general information
Selection Data
FDR
FDL
FDR SS
FMR
 
slack and parr flow dividers selection data  




Maximum Pressure 500 Bar - Accuracy +/- 1%

Ordering Code Displacement per Section Min Inlet per Selection / Lpm Max Inlet per Section / Lpm
FMR2 2CC / Rev 0.5 @ 1 BAR 6@7 BAR
FMR4 4CC / Rev 1 @ < 1 BAR 12 @ 4 BAR
FMR6 6CC / Rev 1.5 @ < 1 BAR 18 @ 3 BAR
FMR9 9CC / Rev 2.25 @ < 1 BAR 27 @ 2 BAR

Results using Hydraulic 32 Oil at 20 °C

Port Sizes: 1/2 BSP Inlet 3/8 BSP Outlet
Material: SG Cast Iron. Hardened Stainless Tool Steel ground Gears and Spindles.
Seals: Viton
Temp: - 20 °C - + 80 °C
Filtration: 10 Microns
Viscosity Range: 10 - 320 CTS
A variety of media can be used, application details to be submitted. All data are factory conditions

General Information


Electrical Data
Connection Cable
Rated operational voltage
24DC V
Rated operational current (le) 200 mA
Time delay before availability 50 ms
Electrical type DC
Utilisation category DC 13
Hysteresis max (H) 15 %
No-load supply current d. 8 mA
Off state current max (lr) 10 μA
Ripple of power supply = 15 %
Switching output PNP
Switching element function NO
Operating frequency (f) 2000 Hz
Voltage drop static max 2 V
Supply voltage max DC (UB) 30 V
Supply voltage min DC (UB) 10 V
Mechanical Data
Number of wires 3 - wire
Rated operating distance (sn) 1,5 mm
Diameter M12 x 1 mm
Assured operating distance 0...1,2 mm Factory set.
Ambient temperature max + 80 °C
Ambient temperature min - 25 °C
Degree of pollution 3
Sensing face material EP (Duroplast)
Housing material 1.4104
Repeat accuracy max. ® = 5 %


General Data
Short Circuit Yes
Degree of protection IP
IP68 per BWN Pr 20
Protected against polarity reversal Yes
Approval CE
Features Oil pressure rated up to 500
Wiring

 

 

 

 


Flow Dividers General Info | Flow Dividers Selection Data | FDR | FDL | FDR Stainless Steel