flow dividers general information
Selection Data
FDR
FDL
FDR SS
FMR
 

FDR SS (Stainless Steel) Flow Divider

 

Stainless Steel FDR Flow Divider

These are manufactured to order.

 

  No. of
elements / outlets
Element capacity Input flow DIM A
(mm)
DIM B
(mm)
DIM C
(mm)
Min @
750 rpm
Standard @
1500 rpm
Max @
3000 rpm
    CC/REV Lpm Lpm Lpm      
FDR 2/2 2 2 3 6 12 42.6 151.0 171.0
FDR 2/4 2 4 6 12 24 49.3 164.3 184.3
FDR 2/6 2 6 9 18 36 55.9 177.6 197.6
FDR 2/9 2 9 13,5 27 54 65.9 197.7 217.7
                 
FDR 3/2 3 2 4,5 9 18 42.6 193.5 213.5
FDR 3/4 3 4 9 18 36 49.3 213.6 233.6
FDR 3/6 3 6 13,5 27 54 55.9 233.5 253.5
FDR 3/9 3 9 20,2 40,5 81 65.9 263.6 283.6
                 
FDR 4/2 4 2 6 12 24 42.6 236.1 256.1
FDR 4/4 4 4 12 24 48 49.3 262.8 282.8
FDR 4/6 4 6 18 36 72 55.9 289.4 309.4
FDR 4/9 4 9 27 54 91 65.9 329.5 349.5
                 
FDR 5/2 5 2 7,5 15 30 42.6 278.7 298.7
FDR 5/4 5 4 15 30 60 49.3 312.0 332.0
FDR 5/6 5 6 22,5 45 90 55.9 345.3 365.3
FDR 5/9 5 9 33,7 67,5 91 65.9 395.4 415.4
                 
FDR 6/2 6 2 9 18 36 42.6 321.2 341.2
FDR 6/4 6 4 18 36 72 49.3 361.2 381.2
FDR 6/6 6 6 27 54 91 55.9 401.2 421.2
FDR 6/9 6 9 40,5 81 91 65.9 461.3 481.3

Maximum pressure 345 bar.

Ordering Code Displacement per Section Min Inlet per Selection / Lpm Max Inlet per Section / Lpm
FDR---/2 2CC / Rev 1,5 6
FDR---/4 4CC / Rev 3 12
FDR---/6 6CC / Rev 4,5 18
FDR---/9 9CC / Rev 6,75 27

Ordering Code Example for Unequal Flow Divider
FDR 4/2.4.4.9

This is a 4 Section Unit with;
One 2cc Section
Two 4cc Sections
One 9cc Section

Total Input flow @ 1500 rpm – 25.5 litre/min

Four Output Flows 1500 rpm of 3, 6, 6 & 13.5 Lpm.

 


Flow Dividers General Info | Flow Dividers Selection Data | FDR | FDL | FDR Stainless Steel